{"id":1812,"date":"2026-10-09T12:44:35","date_gmt":"2026-10-09T12:44:35","guid":{"rendered":"https:\/\/wewinsmartagri.com\/?post_type=product&#038;p=1812"},"modified":"2026-10-09T13:55:57","modified_gmt":"2026-10-09T13:55:57","slug":"rs485-greenhouse-co2-sensor","status":"publish","type":"product","link":"https:\/\/wewinsmartagri.com\/fr\/product\/rs485-greenhouse-co2-sensor\/","title":{"rendered":"Capteur de CO\u2082 RS485 pour la surveillance des serres"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><strong>Capteur de CO\u2082 RS485 pour la surveillance des serres<\/strong>. Measure carbon dioxide concentration for commercial greenhouse ventilation and CO2 monitoring projects.<\/p><h2 class=\"wp-block-heading\">Caract\u00e9ristiques techniques<\/h2><p class=\"wp-block-paragraph\">Le tableau pr\u00e9sente la configuration indiqu\u00e9e. Veuillez v\u00e9rifier la gamme command\u00e9e, la variante de sortie, les accessoires et les crit\u00e8res de r\u00e9ception avant de passer commande.<\/p><figure class=\"wp-block-table\"><table><thead><tr><th>Param\u00e8tre<\/th><th>Sp\u00e9cification<\/th><\/tr><\/thead><tbody><tr><td>Puissance<\/td><td>9 \u00e0 24 V CC<\/td><\/tr><tr><td>Method<\/td><td>Infrared measurement<\/td><\/tr><tr><td>CO2 range<\/td><td>0\u20135,000 ppm<\/td><\/tr><tr><td>R\u00e9solution<\/td><td>1 ppm<\/td><\/tr><tr><td>Pr\u00e9cision indiqu\u00e9e<\/td><td>\u00b1(50 ppm + 5% of reading)<\/td><\/tr><tr><td>Humidit\u00e9 de fonctionnement<\/td><td>0\u201395% RH, sans condensation<\/td><\/tr><tr><td>R\u00e9sultat<\/td><td>RS485 Modbus<\/td><\/tr><\/tbody><\/table><\/figure><h2 class=\"wp-block-heading\">S\u00e9lection et int\u00e9gration syst\u00e8me<\/h2><p class=\"wp-block-paragraph\">Select the range around the crop-management and ventilation needs. Request calibration instructions and any automatic baseline-correction behavior, especially where the greenhouse does not regularly return to outdoor background concentration.<\/p><h2 class=\"wp-block-heading\">Consignes d'installation et d'utilisation<\/h2><p class=\"wp-block-paragraph\">Place the sensor away from a CO2 injection point and verify representative air mixing. Crop responses depend on light, temperature, nutrition and management; the sensor does not guarantee yield improvement. Safety-alarm certification is not established by this product sheet.<\/p><h2 class=\"wp-block-heading\">\u00c9valuation d'un \u00e9chantillon<\/h2><p class=\"wp-block-paragraph\">Avant de passer une commande importante, v\u00e9rifiez que l'\u00e9chantillon s\u00e9lectionn\u00e9 est conforme au cahier des charges convenu, en le testant dans des conditions d'exploitation repr\u00e9sentatives. V\u00e9rifiez le c\u00e2blage, l'alimentation, les unit\u00e9s de sortie et la communication avec le contr\u00f4leur, puis enregistrez les mesures de r\u00e9f\u00e9rence et toute modification de configuration. Convenez des documents requis, de l'emballage et des pi\u00e8ces de rechange dans le cadre du devis.<\/p><h2 class=\"wp-block-heading\">FAQ sur les candidatures<\/h2><h3 class=\"wp-block-heading\">Can it replace a certified personnel-safety CO2 alarm?<\/h3><p class=\"wp-block-paragraph\">The supplied configuration is for process monitoring. Use a separately specified and certified safety system where personnel protection is required.<\/p><h2 class=\"wp-block-heading\">Demander un devis pour un projet<\/h2><p class=\"wp-block-paragraph\">For greenhouse CO2 sensor selection, send the following details so Wewin Smart Agri can help match the configuration and coordinate sample evaluation and a batch quotation:<\/p><ul class=\"wp-block-list\"><li>Expected CO2 range and greenhouse use<\/li><li>Baseline conditions and calibration expectations<\/li><li>Controller interface, sensor locations and quantity<\/li><li>Pays de destination, quantit\u00e9 estim\u00e9e de la commande et d\u00e9lai de livraison requis<\/li><\/ul><p class=\"wp-block-paragraph\"><a href=\"https:\/\/wewinsmartagri.com\/fr\/contact\/\">Envoyez-nous les documents requis pour votre candidature<\/a> pour une analyse de la configuration et un devis. Les informations relatives au projet sont disponibles dans notre <a href=\"https:\/\/wewinsmartagri.com\/fr\/categorie-produit\/capteurs-agricoles\/\">gamme de capteurs agricoles<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Measure carbon dioxide concentration for commercial greenhouse ventilation and CO2 monitoring projects.<\/p>","protected":false},"featured_media":1811,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[66],"product_tag":[],"class_list":["post-1812","product","type-product","status-publish","has-post-thumbnail","product_cat-agricultural-sensors","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/wewinsmartagri.com\/fr\/wp-json\/wp\/v2\/product\/1812","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wewinsmartagri.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/wewinsmartagri.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/wewinsmartagri.com\/fr\/wp-json\/wp\/v2\/comments?post=1812"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wewinsmartagri.com\/fr\/wp-json\/wp\/v2\/media\/1811"}],"wp:attachment":[{"href":"https:\/\/wewinsmartagri.com\/fr\/wp-json\/wp\/v2\/media?parent=1812"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/wewinsmartagri.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1812"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/wewinsmartagri.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1812"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/wewinsmartagri.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1812"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}