J Series Single-Channel Fertigation Unit

The J series single-channel fertigation unit is a pump-injection configuration for commercial irrigation projects. It has one injection channel and timed-start functionality, with EC/pH sensing listed as optional. It is intended for irrigation contractors, equipment distributors and orchard or hillside project buyers whose dosing requirements can be served by a single-channel arrangement.

Configuration review and project quotation available. Confirm connection standards and the selected control package before ordering.

Description

The J series single-channel fertigation unit is a pump-injection configuration for commercial irrigation projects. It has one injection channel and timed-start functionality, with EC/pH sensing listed as optional. It is intended for irrigation contractors, equipment distributors and orchard or hillside project buyers whose dosing requirements can be served by a single-channel arrangement.

Applications

  • Orchard or hillside irrigation projects requiring a specified pump-injection unit.
  • Timed injection of a compatible stock solution through one channel.
  • Equipment procurement where optional measurement and commissioning scope are agreed before purchase.

Application Illustration

J Series Single-Channel Fertigation Unit — AI-generated application illustration
AI-generated application illustration for context only; not an actual installation photograph or an engineering drawing. Confirm the final equipment and connection layout for your project.

The gallery also includes an edited detail view based on the reference product image. Use the confirmed datasheet and drawings for technical selection.

Single-Channel Fertigation Unit Selection

Choose a single-channel arrangement when the project can use one stock-solution injection path. It does not provide simultaneous independent dosing from several stock tanks. If a nutrient recipe requires separate incompatible concentrates or independent acid dosing, review a multi-channel configuration. Optional EC/pH sensors do not by themselves establish closed-loop dosing: the control algorithm, sensor placement and mixing arrangement must also be confirmed.

Technical Configuration

Listed values describe the available configuration. Confirm the current datasheet, dimensional drawing and itemized supply scope before ordering.

ItemConfiguration
SeriesJ
Injection methodPump injection
Injection channelsOne
EC/pH sensorsOptional single-channel EC/pH configuration
Listed electrical supplyAC 380 V, 50 Hz; verify site supply and wiring requirements
Listed total power1.8 kW
Listed injection pump power1.5 kW
ConnectionsDN32; confirm connection standard
Dimensions910 × 510 × 1,130 mm (L × W × H)
Listed start conditionTimed start
Injection capacityConfirm operating range and pump curve for the ordered configuration

Installation and Integration Checks

  • Provide mainline flow and pressure, desired injection rate and stock-solution properties. Pump duty must be matched to the actual installation; a pump’s listed flow/head is not a guaranteed complete-system duty point.
  • Confirm chemical compatibility, filtration, backflow protection and the proposed installation diagram.
  • State whether EC/pH monitoring is required and whether the project needs display-only measurement or verified feedback control.
  • Confirm local electrical supply, installation responsibilities, commissioning, sensor calibration and spare-parts scope.
  • Confirm the selected valve-control interface. Any remote service requires destination connectivity, platform language and account-access review.

Frequently Asked Questions

Are EC/pH sensors included as standard?

No. They are listed as optional for this series. The quotation must identify which instruments and supported functions are supplied.

Is this equivalent to a multi-channel EC/pH fertigation system?

No. This unit provides a single pump-injection channel. Multiple independently dosed concentrates or acid circuits require a separately specified arrangement.

What injection rate should I use for design?

Request the current operating range and pump curve, then check against mainline pressure and the stock solution. The available brochure figures do not establish a guaranteed operating envelope.

Can it run on a different mains voltage?

The listed supply is AC 380 V, 50 Hz. Do not assume other voltages or frequencies are supported; request a confirmed export electrical configuration.

Request a Configuration-Matched Quote

Send the following application details to Wewin for product matching, sample enquiries and an itemized quotation. Agree on acceptance testing and after-sales responsibilities before a bulk order.

  • Crop, irrigation method and installation diagram
  • Minimum/maximum mainline flow and pressure
  • Stock solution, desired injection ratio and operating schedule
  • EC/pH measurement or feedback requirements
  • Destination electrical supply, control interface and quantity